Disposable Veterinary Urinary Catheter

Item Specification
Product name Disposable Veterinary Urinary Catheter
Also called Cat catheter, dog catheter, urinary catheter without balloon, urethral catheter
Cat sizes 1.0 x 130 mm / 1.3 x 130 mm / 1.3 x 160 mm
Dog sizes 1.3 / 1.6 / 2.0 / 2.3 / 2.6 / 3.0 / 3.3 mm x 500 mm
Cat tube LDPE, with side holes at the tip
Dog tube PP
Stylet Stainless steel – supplied or omitted by item
Connector 6:100 Luer, fits a standard syringe
Balloon None – non-balloon catheter
Sterilisation EO sterilised to ISO 11135, individually packed
MOQ 100 cartons
Lead time About 30 days after deposit

Specifications

Sterile, single use urinary catheters for cats and dogs: non-balloon, six cat sizes across three lengths, seven dog sizes at 500 mm, with or without a stylet, EO sterilised and individually packed.

Two Species, Two Ranges

A cat urethra is small and delicate; a dog’s is larger and takes a stiffer tube. That single anatomical fact is why the two ranges are built differently rather than just scaled.

Cat — LDPE, 1.0 and 1.3 mm. The tube is soft and thin on purpose: it has to follow a narrow, easily traumatised urethra, and a supple tube finds its way round a curve instead of pushing through it. Lengths run 130 mm for a routine catheterisation and 160 mm where the anatomy or the patient’s size calls for more tube to hold.

Dog — PP, 1.3 to 3.3 mm, 500 mm long. A longer, stiffer tube for a longer urethra: 1.3 and 1.6 mm for cats and small breeds, 2.0 to 2.6 mm for medium and large dogs, 3.0 and 3.3 mm for the largest patients and for drainage work where flow matters more than finesse. Seven diameters means you can match the patient instead of forcing one size to fit.

Both are non-balloon. In a small patient the urethra is short and thin, and an inflated balloon presses on a wall that has very little give; a non-balloon catheter removes that risk entirely, and there is nothing to deflate before the catheter comes out.

With or Without a Stylet

This is the choice that decides how the catheter handles, and it is the one most often ordered wrong.

With a stylet, a stainless steel wire sits inside the tube and stiffens it. The assembly pushes rather than follows — you can direct a fine catheter through a difficult urethra that a soft tube would simply fold against. Once the tip is where it should be, the stylet is withdrawn and the catheter is left in place, soft again.

Without a stylet, the catheter is as soft as the tube allows. It is the version for routine catheterisation, for a patient that is already relaxed, and for anyone who prefers to work without a wire inside the lumen where it can be forgotten.

Both are supplied. The cat range covers both in 1.0 and 1.3 mm at 130 mm, with the 160 mm length in the stylet version; the dog range runs on the plain tube.

Why the Range Runs This Wide

Nobody picks a catheter from a catalogue and hopes. It is chosen at the patient, by the clinician, on the day — which means the shelf has to hold the whole range, not the two sizes that sell best.

A clinic keeps 1.0 and 1.3 mm for cats because the same species is not the same patient: a small queen and a large tom are not served by the same tube, and the difference between 130 and 160 mm is whether there is enough catheter to hold once the tip is in place.

The dog range runs 1.3 to 3.3 mm for the same reason at a bigger scale — a toy breed and a large working dog sit at opposite ends of it, and the sizes in between are what let a practice match the tube to the patient instead of forcing the nearest one.

That is also why mixed cartons are worth arranging. A practice ordering one diameter runs out of it the week a different case walks in.

EO Sterile, Individually Packed

The catheters are sterilised with ethylene oxide to ISO 11135 and packed one to a pouch. EO is the right process for this product: it sterilises at low temperature, so the LDPE and PP tube keeps its flexibility and its exact dimensions instead of softening or distorting the way heat would.

Individually packed matters as much as sterile. A catheter is opened at the patient, used once and discarded — a pouch that opens cleanly at the point of use is the only format that keeps the sterility claim honest. A bulk bag would be sterile until the first time it was opened.

Each catheter carries side holes at the tip so urine enters through more than one opening, and a 6:100 Luer connector at the proximal end that takes a standard syringe for sampling, emptying or flushing.

Packing and Ordering

One catheter to a sterile pouch, packed to your carton count. Minimum order is 100 cartons, about 30 days from deposit. Sizes and the stylet option are ordered by item, so a mixed carton is possible if the lines are kept separate.

For the rest of a veterinary procedure, the sterile op cover and the long glove sit in the same range. Send the species, the diameter, the length and whether a stylet is needed to request a quote. If you are choosing between two diameters, take a sample of each — the difference on paper is half a millimetre, and in the hand it decides the case.

Frequently Asked Questions

Why is the cat catheter LDPE and the dog catheter PP?

Because of the urethra each has to pass. LDPE is softer and follows a narrow, delicate tract; PP is stiffer, which suits a larger patient where the tube needs to be pushed rather than threaded.

What does the stylet do?

It stiffens the catheter so it can be directed through a difficult urethra. The wire is withdrawn once the tip is in place, leaving the soft tube behind.

Is it a balloon catheter?

No. These are non-balloon catheters — nothing is inflated inside the urethra, and nothing has to be deflated before removal.

Can we order a mix of sizes in one carton?

Yes, provided the items are kept as separate lines so the packing list stays accurate. Tell us the split and we will quote it that way.